The third phase of a new born gerotor pump project
The required parameters of this
third phase were the same geometrical parameters of the second
phase, volumetric characteristics module, in addition to material and fluid parameters. By using the contact stress approach, an iterative method automatically calculates contact stress on each active contact point.
[see References 4 and 6]